Horizontal Multistage Centrifugal Pumps for Moderate-to-High Head
For plants and buildings that need steady pressure from a low-profile pump. We supply horizontal multistage centrifugal pumps in the CHL, CHLF and CHLF(T) series for water supply, boosting and light process duty.
- CHL and CHLF series
- Low-profile layout
- Moderate-to-high head

Several stages, one horizontal pump
A horizontal multistage centrifugal pump has two or more impellers on a common horizontal shaft. Each stage works almost like a separate pump, adding head to the liquid before passing it to the next. This makes the design well suited to services with moderate-to-high total dynamic head where a single impeller would be pushed beyond its efficient range.
The horizontal layout keeps the pump low and easy to reach, which helps where headroom is limited or where the pump sits on a skid or under equipment. We supply the CHL series, the CHLF series and the CHLF(T) series, and help you select the model, materials and stage count that match your flow and pressure.
Key highlights
- Two or more impellers for moderate-to-high total dynamic head
- Low-profile horizontal layout for limited headroom
- CHL, CHLF and CHLF(T) series available
- Compact enough for skids and packaged systems
- Suits clean water and light, non-abrasive liquids
What a horizontal multistage pump offers
Multiple stages
Each impeller adds head in turn, so the pump reaches higher pressures than a single-stage unit while staying compact on its baseplate.
Low installation height
The horizontal shaft keeps the overall height low, ideal under staircases, in shallow pump pits or beneath equipment where vertical pumps will not fit.
Easy access
Motor, seal and connections are reachable from the side, which makes routine inspection and seal replacement simpler for maintenance teams.
Stainless options
CHLF and CHLF(T) series pumps offer stainless steel wetted parts for clean, softened or mildly aggressive water where corrosion resistance matters.
Steady pressure
The multistage design delivers stable discharge pressure across the working range, useful for domestic supply, washing lines and small booster sets.
Flexible controls
Pairs easily with pressure switches, pressure tanks or variable speed drives to suit on-demand supply and constant-pressure applications.
Typical applications
Not sure this is the right fit?
Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.
From enquiry to a running pump
A simple, engineer-led process — so you get the right pump the first time.
-
Share your duty
Tell us the liquid, flow, head, temperature and where the pump will run.
-
Get a sized proposal
Our engineers select the pump type, model, material and motor that fit the duty point.
-
Supply & installation
We supply the pump or system and can install, align and commission it on site.
-
Service that continues
Preventive maintenance, spares and repairs keep the system running efficiently.
Horizontal Multistage Centrifugal Pumps — FAQs
Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.
What is the difference between horizontal and vertical multistage pumps?
Both use several impellers in series to build pressure. A horizontal pump has a horizontal shaft and a lower overall height, so it suits locations with limited headroom and is easy to reach for service. A vertical pump stands on a smaller base, saving floor area. The choice usually depends on space, pipe layout and the required duty point.
What duty range suits a horizontal multistage pump?
These pumps are typically used for moderate-to-high head at low to moderate flow, such as boosting supply to several floors, feeding washing lines or supplying small process loads. For very high flows at low head, a single-stage end suction pump is usually more economical. Share your flow and head and we will confirm which design fits best.
Which series should I choose: CHL, CHLF or CHLF(T)?
The right series depends on your flow, head, liquid and installation. All three are horizontal multistage designs, with CHLF and CHLF(T) commonly chosen where stainless steel wetted parts are needed. Send us your duty point, liquid details and site constraints, and we will recommend the most suitable series and model.
Are horizontal multistage pumps self-priming?
Most horizontal multistage centrifugal pumps are not self-priming. The pump casing and suction line must be filled with liquid before starting, and a foot valve is usually fitted when the pump lifts water from below. For the most reliable operation, install the pump with a flooded suction wherever possible.
What details should I send for a quote?
Please send the required flow in m³/h or litres per minute, total head in metres or pressure in bar, liquid type and temperature, suction condition, available power supply and the application. If you are replacing an existing pump, a photo of its nameplate helps us match connections and performance.
How do I keep a horizontal multistage pump running reliably?
Never run the pump dry, keep the suction strainer clean and avoid operating against a fully closed discharge valve for long periods. Check periodically for seal leakage, abnormal noise or vibration, and confirm that the pressure matches the design duty. Address small leaks early to avoid damage to bearings and the motor.
Find the right horizontal multistage pump for your site
Send your flow, head and installation details and we will recommend a suitable CHL or CHLF series model.