Skip to content
+91 93630 47778contact@pumpscart.com Ambattur, Chennai · Supplying across India
Misting & Fogging

High Pressure Misting System Pumps for Cooling and Dust Control

Misting pumps for contractors, factories and outdoor venues that need fine, fast-evaporating mist for cooling, dust suppression or odour control, supplied in low, medium and high pressure ranges with spares support.

  • 7 to 300 bar
  • Fine micron mist
  • Spares available
High Pressure Misting System Pumps for Cooling and Dust Control

Talk to a pump engineerSend your flow, head and liquid — we suggest the right model.
Misting & Fogging

Finer droplets, faster cooling, wider coverage

A misting pump raises ordinary supply pressure, around 7 bar, to the level needed to atomise water through micro nozzles. At about 70 bar (1000 psi) the droplets are roughly 5 microns in size and flash-evaporate almost instantly, pulling heat from the surrounding air. In dry conditions this can bring the area temperature down by up to 12 °C without wetting people, floors or equipment.

Pumping Solutions supplies and integrates misting pumps from international and Indian brands, covering low, medium and high pressure systems from 7 bar (100 psi) up to 300 bar (4500 psi). We help you match pump flow and pressure to the number of nozzles, line length and application, whether it is cooling a restaurant terrace, settling dust at a crusher or controlling odour at a waste facility.

Key highlights

  • Pressure range from 7 bar up to 300 bar
  • Around 5-micron droplets at about 70 bar
  • Cooling of up to 12 °C in dry conditions
  • For cooling, dust suppression and odour control
  • Residential, commercial and industrial systems
  • Pumps sourced from international and Indian brands
Why it works

What a well-matched misting pump delivers

Evaporative cooling

Micron-sized droplets evaporate before they land, absorbing heat from the air and cooling open or semi-open spaces without wetting surfaces.

Dust suppression

Fine mist captures airborne dust particles and settles them, helping crushers, stockyards, demolition and construction sites stay cleaner.

Odour control

Mist lines can disperse odour-neutralising solutions evenly over landfills, sewage treatment plants and waste transfer stations, reducing nuisance for neighbours and workers.

Right pressure tier

Low, medium and high pressure pumps let you balance droplet size, coverage and budget for the duty you actually need.

System integration

We match pump flow to nozzle count and line length, and advise on filters, valves and controls for a balanced system.

Spares support

Seals, valves and service kits for the pumps we supply are kept available, so maintenance does not leave the system idle.

Technical data

Misting pump range at a glance

Pressure range 7 bar (100 psi) to 300 bar (4500 psi)
Pressure tiers Low, medium and high pressure
Typical inlet pressure About 7 bar (100 psi) mains supply
Typical high pressure duty About 70 bar (1000 psi)
Droplet size at high pressure Around 5 microns
Cooling effect Up to 12 °C
Brands supplied Interpump, Pratissoli, CAT, Annovi Reverberi, Hawk, Ebara, Xylem and others
Applications

Misting pump applications

  • Outdoor and patio cooling
  • Restaurants and resorts
  • Factory shed cooling
  • Poultry and dairy farms
  • Greenhouses
  • Dust suppression at crushers
  • Odour control at landfills
  • Construction site dust control

Not sure this is the right fit?

Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.

How we work

From enquiry to a running pump

A simple, engineer-led process — so you get the right pump the first time.

  1. Share your duty

    Tell us the liquid, flow, head, temperature and where the pump will run.

  2. Get a sized proposal

    Our engineers select the pump type, model, material and motor that fit the duty point.

  3. Supply & installation

    We supply the pump or system and can install, align and commission it on site.

  4. Service that continues

    Preventive maintenance, spares and repairs keep the system running efficiently.

FAQs

High Pressure Misting System Pump — FAQs

Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.

What is the difference between low, medium and high pressure misting?

Low pressure systems run close to mains pressure and produce larger droplets that can wet surfaces. Medium pressure gives finer mist for semi-open areas. High pressure systems, typically around 70 bar and above, produce very fine droplets that evaporate quickly, giving the best cooling with minimal wetting. The right tier depends on the space, humidity and how dry the area must stay.

How do I size a misting pump?

Sizing starts with the number of nozzles and their flow rating at the target pressure. Add the line length, number of zones and any elevation, then select a pump whose flow covers all nozzles with a small margin. Share your layout drawing or area dimensions and intended use, and we will work out the pump capacity and pressure for you.

Does misting work in humid climates?

Evaporative cooling is most effective when the air is dry. In humid coastal conditions the cooling effect is lower because the air already holds more moisture, so droplets evaporate more slowly. High pressure systems still help, as finer droplets evaporate more readily, but expectations should be set accordingly. For dust suppression, humidity matters much less.

Can misting pumps be used for dust suppression?

Yes. Fine mist binds airborne dust particles and brings them down, which is useful at crushers, conveyor transfer points, stockpiles and demolition sites. Dust suppression often uses medium to high pressure with nozzles placed close to the dust source. We can recommend a pump and nozzle arrangement based on the dust source and the area to be covered.

What water quality is needed for a misting system?

Micro nozzles have very small orifices, so water should be clean and filtered to avoid blockages. Hard water can leave scale on nozzles over time, and many systems use softening or treatment upstream of the pump. A good inlet filter also protects the pump valves and seals and helps the system run longer between services.

What maintenance does a misting pump need?

Check and clean inlet filters regularly, inspect nozzles for scaling or blockage, and keep the pump oil at the correct level where applicable. Plunger seals and valves are wear parts and are replaced at intervals depending on running hours and water quality. We keep spares available for the pumps we supply to keep downtime short.

Get a misting pump matched to your nozzles and duty

Send your nozzle count, area and application, and we will recommend the pump pressure and flow your misting system needs.