Chiller Pumps for Chilled Water and Condenser Water Circuits

For HVAC consultants, chiller plant operators and contractors who need reliable chilled water flow. We supply pumps sized to chiller evaporator and condenser requirements for steady capacity and efficient plant operation.

  • Primary and secondary loops
  • Sized to chiller flow
  • End suction and multistage
Chiller Pumps for Chilled Water and Condenser Water Circuits

Talk to a pump engineerSend your flow, head and liquid — we suggest the right model.
Chillers & Chilled Water

Pumps that keep your chiller plant at capacity

A chiller removes heat from water, which is then circulated to air handling units, fan coils or process equipment. The chiller pump must deliver the exact flow the evaporator is rated for. Too little flow causes low-temperature trips and risks freezing; too much wastes energy and erodes tubes. On water-cooled chillers, condenser pumps carry heat to the cooling tower.

Chiller plants are commonly arranged as primary-only variable flow, or primary-secondary systems with constant flow through each chiller and variable flow to the building. Each layout changes how pumps are selected and controlled. In both layouts chiller pumps run for long hours, so their efficiency has a direct impact on the plant's overall energy use per tonne of refrigeration.

Pumping Solutions supplies NISO-k series single-stage end suction pumps and ZS series horizontal single-stage pumps for high-flow chilled and condenser water duty, and CHL and CHLF(T) series horizontal multistage pumps for smaller chillers and high-resistance process chiller circuits. We size each pump from your chiller schedule, design temperatures and piping layout, and check minimum flow limits.

Key highlights

  • Flow matched to chiller evaporator and condenser ratings
  • NISO-k end suction and ZS single-stage for high flow
  • CHL and CHLF(T) multistage for compact and process chillers
  • Primary, secondary and condenser water pump duties
  • Variable speed options for variable primary flow plants
  • Duty and standby pumps for each chiller circuit
Why it works

Chiller pump selection that protects capacity

Evaporator flow protection

Pumps are sized to the chiller's rated evaporator flow, avoiding low-flow trips and freeze risk while keeping the chiller at full capacity.

Condenser water duty

Condenser pumps are selected for tower static height, nozzle pressure and condenser losses, so heat rejection stays steady in peak summer.

Plant-level efficiency

Selecting pumps near best efficiency and matching them to the plant's control strategy lowers total kW per tonne of the chiller plant.

Variable primary ready

Variable speed pumps let flow follow building load while respecting each chiller's minimum flow, reducing pumping energy at part load.

Range of pump types

End suction and single-stage pumps handle large comfort cooling plants; multistage pumps suit compact air-cooled and process chillers.

Redundancy built in

Dedicated or headered duty and standby arrangements keep chilled water flowing during maintenance or a pump fault, protecting comfort and process cooling.

Applications

Chiller pumping duties

  • Primary chilled water pumps
  • Secondary distribution pumps
  • Condenser water pumps
  • Air-cooled chiller packages
  • Process chillers
  • District cooling plants
  • Data centre cooling
  • Ice and thermal storage

Not sure this is the right fit?

Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.

How we work

From enquiry to a running pump

A simple, engineer-led process — so you get the right pump the first time.

  1. Share your duty

    Tell us the liquid, flow, head, temperature and where the pump will run.

  2. Get a sized proposal

    Our engineers select the pump type, model, material and motor that fit the duty point.

  3. Supply & installation

    We supply the pump or system and can install, align and commission it on site.

  4. Service that continues

    Preventive maintenance, spares and repairs keep the system running efficiently.

FAQs

Pump for Chillers and HVAC — FAQs

Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.

How is a chiller pump sized?

Flow comes from the chiller's rated evaporator or condenser flow, or from cooling capacity and design temperature difference. Head is the sum of losses through the chiller, piping, valves, strainers and, for condenser pumps, the cooling tower static and nozzle pressure. Send your chiller schedule and piping layout and we will calculate both.

What is the difference between primary and secondary chilled water pumps?

In a primary-secondary system, primary pumps run at constant flow through each chiller, protecting the evaporator. Secondary pumps take water from a common header and vary flow to the building load. In variable primary flow systems, a single set of variable speed pumps does both jobs, with controls holding each chiller's minimum flow.

Which pump series suit chiller plants?

For large comfort cooling plants, NISO-k series end suction and ZS series horizontal single-stage pumps handle high flow at moderate head. For smaller air-cooled chillers and process chillers with higher circuit resistance, CHL and CHLF(T) series horizontal multistage pumps are often a better fit.

What happens if chilled water flow is too low?

Low flow reduces heat transfer in the evaporator and can drive leaving water temperature too low, causing safety trips or, in the worst case, freezing and tube damage. Chillers have flow switches to prevent this. Correct pump sizing, clean strainers and well-balanced piping keep flow within the allowed range.

Can variable speed drives be used on chiller pumps?

Yes. Variable speed is common on secondary and variable primary pumps and on condenser pumps in many plants. The control system must keep each running chiller above its minimum evaporator flow and manage chiller staging. Done well, variable speed reduces pumping energy substantially at part load.

Should each chiller have its own pump?

Dedicated pumps per chiller simplify control and staging. Headered pumps serving all chillers give flexibility and easier standby. Both are common; the choice depends on chiller sizes, plant layout and control philosophy. We can review your design and suggest pump quantities and standby arrangement.

Get chilled and condenser water pumps sized for your chillers

Share your chiller schedule, design temperatures and piping layout, and we will recommend pumps for each chiller circuit.