Integrated Control Panel for Fire Fighting Pump Systems
For fire pump rooms that need clear control, fault indication and alarms in one enclosure. This integrated panel provides remote start and stop, LED fault display and an audible hooter for main, jockey and standby pumps.
- IP55 or IP65
- Remote start and stop
- LED fault alarms

Control and alarms for the whole fire pump set
The integrated control panel brings fire pump control and monitoring into one enclosure. It accepts remote start and stop commands from push button stations, so pumps can be operated from a safe location. When a fault occurs, the matching LED flashes and the same signal is sent to output terminals for remote indication.
A hooter on the panel gives an audible alarm, driven by a dedicated hooter relay, so operators notice faults immediately. The input faults that trigger alarms can be selected on site during commissioning, letting the panel match the specific pumps, sensors and alarms in your system. This avoids unnecessary alarms and keeps the indications meaningful for operators.
The enclosure is mild steel, powder coated in fire red, with standard sheet thickness of 14 or 16 SWG. Cable entry can be top or bottom, and protection is IP55 or IP65 as required. The panel suits fire, municipal, industrial and water treatment pumping systems. We build the panel to suit your pump ratings and starting method.
Key highlights
- Remote start and stop from push button stations
- Flashing LED fault indication with remote outputs
- Hooter with relay for audible alarm
- Input faults selectable on site
- Fire red powder-coated MS, 14/16 SWG
- Top or bottom entry, IP55 or IP65
What the integrated panel provides
Remote operation
Inputs from remote push button stations let operators start and stop pumps from a safe point away from the pump room.
LED fault indication
Each fault has its own LED that flashes when triggered, making it quick to identify the cause during an alarm.
Audible hooter alarm
A panel-mounted hooter, driven by its own relay, alerts staff to faults even when no one is watching the panel.
Site-selectable inputs
Fault inputs can be chosen during commissioning, so the panel matches the pumps, sensors and alarms in your system.
IP55 or IP65 enclosure
Powder-coated mild steel enclosures are built to IP55 or IP65 as required, protecting controls from dust and water.
Remote indication outputs
Fault signals are repeated on output terminals, allowing connection to remote annunciators, fire alarm panels or building management systems.
Panel construction and features
| Enclosure material | Mild steel, powder coated |
|---|---|
| Finish | Fire red powder coat |
| Sheet thickness | 14/16 SWG |
| Cable entry | Top or bottom |
| Protection | IP55 or IP65 as required |
| Controls | Remote start/stop from push button stations |
| Fault indication | Flashing LEDs with remote output terminals |
| Alarm | Panel-mounted hooter with hooter relay |
| Fault inputs | Selectable at site |
Where it is used
Not sure this is the right fit?
Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.
From enquiry to a running pump
A simple, engineer-led process — so you get the right pump the first time.
-
Share your duty
Tell us the liquid, flow, head, temperature and where the pump will run.
-
Get a sized proposal
Our engineers select the pump type, model, material and motor that fit the duty point.
-
Supply & installation
We supply the pump or system and can install, align and commission it on site.
-
Service that continues
Preventive maintenance, spares and repairs keep the system running efficiently.
Integrated Panel for Fire Fighting System — FAQs
Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.
What does an integrated fire pump panel control?
It controls and monitors the fire pump set, typically the main electric pump, jockey pump and interfaces for a diesel standby. It handles start and stop commands, displays faults on LEDs, repeats them on output terminals and sounds a hooter. The exact scope is set to match your pump configuration.
Should I choose IP55 or IP65?
IP55 protects against dust and water jets and suits most indoor pump rooms. IP65 is dust-tight and suits damp, dusty or semi-outdoor locations. Tell us where the panel will be installed and we will recommend the appropriate protection. Outdoor panels may also need a canopy.
Can the panel connect to a building management system?
The panel repeats fault signals on output terminals, which can be wired to remote annunciators, fire alarm panels or a building management system. Share the signals you need to monitor remotely so we can include the right terminals. We can label terminals to match your drawings.
Which faults can the panel indicate?
Fault inputs are selectable on site, so the panel can be set up for the conditions relevant to your system. Typical examples include pump trip, phase failure, low water level and failure to start. We finalise the list with you during design and commissioning.
What is the difference between 14 and 16 SWG?
SWG is the standard wire gauge for sheet thickness, where a lower number means thicker steel. 14 SWG is thicker and more rigid, often chosen for larger panels, while 16 SWG suits smaller enclosures. Selection depends on panel size and specification.
What details do you need to quote a panel?
Send the number and ratings of pumps, starting method, diesel standby details if any, required remote signals, installation location, preferred protection level and any consultant specification. A single-line diagram or pump room layout helps us design the panel accurately. This avoids changes later.
Get a fire pump control panel built for your pump set
Share your pump ratings, starting method and required alarms, and we will propose a panel to match your system.