Skip to content
+91 93630 47778contact@pumpscart.com Ambattur, Chennai · Supplying across India
Inline Pumps

Vertical Inline Circulation Pump for HVAC and Water Supply

For HVAC chilled and condenser water, cooling towers and water supply systems that move large volumes through a pipeline. This single-stage inline pump fits straight into the pipe and can be serviced without disturbing it.

  • Up to 600 m³/h
  • Service without unpiping
  • Up to 150 °C
Vertical Inline Circulation Pump for HVAC and Water Supply

Talk to a pump engineerSend your flow, head and liquid — we suggest the right model.
Inline Pumps

A pump that becomes part of the pipeline

This vertical inline circulation pump is a single-stage centrifugal pump fitted with a standard motor and mechanical seal. The pump body is equivalent to a section of pipeline, with horizontal inlet and outlet on the same axis. It fits directly into a straight pipe run, saving floor space in plant rooms and service shafts.

The top pull-out construction means the motor, impeller and seal lift out from above while the casing stays in the line. Repairs can be done without removing the pipework, which shortens downtime on HVAC and process circuits. Flows range from 5 to 600 m³/h, with heads up to 9 bar and motors up to 200 kW.

Pumps run at 2900 or 1450 rpm and handle liquids from -15 °C to 150 °C. The casing is cast iron as standard with CI or SS-304 impellers, and complete construction is available in SS304 (CF8), SS316 (CF8M), gunmetal (LG2) or duplex stainless steel for more demanding liquids. Tell us the liquid and we will recommend the most suitable construction.

Key highlights

  • Flow 5–600 m³/h; head up to 9 bar
  • Liquid temperature -15 °C to 150 °C
  • Top pull-out design, serviced without unpiping
  • 2900 or 1450 rpm, motors up to 200 kW
  • CI, SS304, SS316, gunmetal or duplex options
  • Compact inline layout saves floor space
Why it works

Why plant engineers choose inline pumps

Inline installation

Inlet and outlet on one horizontal axis let the pump sit directly in the pipe run, with no baseplate or coupling alignment needed.

Top pull-out service

The rotating assembly lifts out from above while the casing stays in place, so seals and impellers are replaced without breaking pipe joints.

High-volume circulation

Flows up to 600 m³/h suit chilled water, condenser water and cooling tower loops in large buildings and industrial plants.

Hot water capable

Rated for liquids from -15 °C to 150 °C, covering chilled water, heating circuits and hot process water in one design.

Wide material choice

Cast iron, SS304, SS316, gunmetal and duplex options let you match the pump to clean water, seawater or mildly aggressive liquids.

Two speed options

2900 rpm gives compact high-head selections, while 1450 rpm offers quieter running and lower wear on large circulation duties.

Technical data

Performance range

Flow range (Q) 5.0–600.0 m³/h
Delivery head (H) Max. 9 bar
Liquid temperature -15 °C to 150 °C
Speed (n) 2900 rpm or 1450 rpm
Power (P) Up to 200 kW
Material of construction Cast iron with CI or SS impeller; SS304 (CF8); SS316 (CF8M); gunmetal (LG2); duplex SS
Applications

Where inline circulation pumps are used

  • HVAC chilled water
  • Cooling tower circuits
  • Heat exchanger loops
  • Urban water supply
  • Industrial water supply
  • Inline pressure boosting
  • Textile industry
  • Paper and pulp
  • Water circulation systems

Not sure this is the right fit?

Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.

How we work

From enquiry to a running pump

A simple, engineer-led process — so you get the right pump the first time.

  1. Share your duty

    Tell us the liquid, flow, head, temperature and where the pump will run.

  2. Get a sized proposal

    Our engineers select the pump type, model, material and motor that fit the duty point.

  3. Supply & installation

    We supply the pump or system and can install, align and commission it on site.

  4. Service that continues

    Preventive maintenance, spares and repairs keep the system running efficiently.

FAQs

Vertical In line Circulation Pump — FAQs

Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.

What are the advantages of an inline pump over an end suction pump?

An inline pump fits directly in a straight pipe run, needs no baseplate and takes up less floor space. With top pull-out design it can be serviced without disturbing pipework. End suction pumps can offer wider selection at very high flows, but for HVAC and circulation duties the inline pump is typically quicker to install and easier to maintain.

Should I choose 2900 rpm or 1450 rpm?

A 2900 rpm pump is smaller and lower in cost for a given duty. A 1450 rpm pump runs quieter, wears more slowly and is often preferred for continuous HVAC duty or large flows. Share the duty point and operating hours, and we will compare both options for efficiency and life-cycle cost.

Can the pump be used for hot water?

Yes. The range handles liquid temperatures from -15 °C up to 150 °C. For hot water, the mechanical seal and elastomers are selected for the temperature, and system pressure must keep the water from flashing at the pump inlet. Tell us the operating temperature and system pressure when you enquire.

Which material should I select?

Cast iron with a CI or SS-304 impeller suits most chilled water and clean water circuits. SS304 or SS316 casings suit treated or demineralised water, gunmetal suits seawater and brackish water, and duplex steel suits more corrosive liquids. Send the water analysis or liquid details so we can recommend the right construction.

Can inline pumps be fitted with a VFD?

Yes. Inline pumps with standard motors are commonly run on variable frequency drives in HVAC systems, adjusting speed to match changing load. Typically this reduces energy use significantly at part load. We can advise on motor suitability and controls for variable speed operation.

What information do you need to size an inline pump?

Send the required flow in m³/h, the system head or pressure drop, liquid and temperature, preferred speed, pipe size and power supply. For HVAC, the chiller or cooling tower flow rate and the circuit pressure drop are usually enough to make a first selection.

Get the right inline circulation pump for your system

Send your flow, head and liquid details, and we will recommend the size, speed and material that suit your circuit.