Skip to content
+91 93630 47778contact@pumpscart.com Ambattur, Chennai · Supplying across India
Vertical Multistage Pumps

CDL Series Vertical Multistage Centrifugal Pump

For boiler feed, pressure boosting, RO and HVAC duties that need high head from a small footprint. The CDL series gives stainless steel hydraulics with cast iron inlet and outlet, sized to your flow and pressure.

  • 305 m max head
  • SS-304 hydraulics
  • In-line ports
CDL Series Vertical Multistage Centrifugal Pump

Talk to a pump engineerSend your flow, head and liquid — we suggest the right model.
Vertical Multistage Pumps

High head in a compact vertical footprint

The CDL series is a close-coupled vertical multistage centrifugal pump built from pressed stainless steel. Impellers, diffusers and the outer sleeve are SS-304, while the inlet and outlet castings are cast iron. Suction and discharge sit on the same line, so the pump drops straight into a pipe run and takes up very little floor space.

Stages are stacked on one shaft, so pressure builds step by step without needing a larger motor speed or a bigger casing. The range covers flows from 0.4 to 240 m³/h and heads up to 305 m (30.5 bar), with motors up to 110 kW at 2900 rpm. Single-phase motors are available up to 2.2 kW.

Motors up to 7.5 kW are face mounted and larger ratings are flange mounted, all standard TEFC frames with Class F insulation and IP55 protection. Standard pumps handle liquids from -15 °C to +70 °C, and high-temperature versions can be supplied on request. We help you choose the stage count and motor that match your duty point.

Key highlights

  • Flow 0.4–240 m³/h; head up to 305 m (30.5 bar)
  • SS-304 wetted hydraulics with cast iron inlet and outlet
  • In-line suction and discharge for simple pipework
  • Standard TEFC motors up to 110 kW, IP55, Class F
  • Single-phase option up to 2.2 kW
  • High-temperature versions available on request
Why it works

Why engineers specify the CDL series

Multistage hydraulics

Stacked stainless steel impellers build pressure in steps, giving high head at 2900 rpm without an oversized pump or casing.

In-line connections

Suction and discharge on the same axis let the pump fit directly into a straight pipe run, which keeps installation simple and compact.

Stainless steel wetted parts

SS-304 impellers, diffusers and sleeve resist corrosion from clean water and slightly aggressive liquids, protecting efficiency over a long service life.

Standard motors

Face-mounted motors up to 7.5 kW and flange-mounted motors above that use standard TEFC frames, so replacements are easy to source.

Service-friendly build

A close-coupled vertical layout with few components keeps routine inspection and seal replacement straightforward for in-house maintenance teams.

Wide duty coverage

Flows from 0.4 to 240 m³/h and power up to 110 kW cover small boosters through to large boiler feed duties.

Technical data

CDL series performance range

Flow range (Q) 0.4–240.0 m³/h
Delivery head Max. 305 m (30.5 bar)
Liquid temperature -15 °C to +70 °C (high-temperature versions on request)
Material of construction SS-304 with CI inlet and outlet
Speed (n) 2900 rpm
Power (P) Up to 110 kW
Motor TEFC, face mounted up to 7.5 kW, flange mounted above; Class F, IP55
Single-phase option Up to 2.2 kW
Applications

Where the CDL series is used

  • High-pressure boiler feed
  • Condensate systems
  • HVAC cooling circuits
  • RO and water treatment
  • Water softening plants
  • Industrial cleaning systems
  • Municipal pressure boosting
  • High-rise building boosters
  • Drip and sprinkler irrigation
  • Fire fighting systems

Not sure this is the right fit?

Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.

How we work

From enquiry to a running pump

A simple, engineer-led process — so you get the right pump the first time.

  1. Share your duty

    Tell us the liquid, flow, head, temperature and where the pump will run.

  2. Get a sized proposal

    Our engineers select the pump type, model, material and motor that fit the duty point.

  3. Supply & installation

    We supply the pump or system and can install, align and commission it on site.

  4. Service that continues

    Preventive maintenance, spares and repairs keep the system running efficiently.

FAQs

Vertical Multistage Centrifugal Pump — FAQs

Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.

What is the difference between the CDL and CDLF series?

The CDL series uses SS-304 hydraulics with cast iron inlet and outlet castings, which suits clean water, boiler feed and general boosting. The CDLF series is built fully in stainless steel, SS-304 or SS-316, for hygienic, demineralised or more aggressive liquids. If your liquid is clean water and cost matters, CDL is usually the practical choice. Tell us the liquid and we will recommend the right version.

What information do you need to size a CDL pump?

Send the required flow in m³/h, the total head or discharge pressure, the liquid and its temperature, suction conditions (flooded or lift), available power supply and whether the pump runs continuously or intermittently. With these we can select the number of stages and the motor rating so the pump runs close to its best efficiency point.

Can a CDL pump be used for boiler feed?

Yes. Boiler feed is one of its main duties because the multistage design delivers high pressure at modest flows. Standard pumps handle liquids up to 70 °C, so for hotter feed water a high-temperature version should be specified. Share your boiler pressure, feed temperature and steam output so we can confirm the right model and seal arrangement.

Is a single-phase motor available?

Single-phase motors are available up to 2.2 kW, which suits smaller boosting duties in buildings, farms and small workshops. Larger ratings use three-phase TEFC motors up to 110 kW. If you only have a single-phase supply and need more power, we can discuss alternative arrangements such as a variable speed drive with a three-phase motor.

How do I maintain a vertical multistage pump?

Keep the pump primed and never run it dry, check the mechanical seal for leaks, and listen for changes in noise or vibration. Typically motor bearings and the mechanical seal are the main wear items. Because the pump is close coupled with in-line ports, seal and motor work can usually be done without disturbing the pipework.

Why choose a vertical multistage pump over an end suction pump?

A vertical multistage pump produces far higher head from a small footprint, which is ideal for boosting, boiler feed and RO. An end suction pump is better suited to high flow at lower head, such as circulation and transfer. For high pressure at moderate flow, the multistage design is typically more efficient and easier to fit into a plant room.

Get the right CDL pump sized for your duty

Share your flow, head and liquid details and our team will recommend the stage count and motor that suit your system.