HP Series Horizontal High Pressure Pump
For membrane desalination, high-pressure boiler feed and industrial cleaning that need very high pressure at moderate flow. The HP series delivers up to 718 m head with balanced, back-to-back impellers.
- 718 m max head
- 75 bar working pressure
- Balanced impellers

Very high pressure with balanced hydraulics
The HP series is a horizontal high-pressure pump that can be supplied as a single pump or as two pumps assembled in series into one pump set. Its impellers are installed back to back, which balances the large axial thrust that builds up at high pressure and reduces load on the bearings.
The range covers flows from 16 to 55 m³/h with heads up to 718 m (71.8 bar) and a maximum working pressure of 75 bar. Power goes up to 55 kW × 2 for paired sets at 2900 rpm, and liquid temperatures from -15 °C to +70 °C are covered.
Wetted parts are available in SS-304, SS-316 and SS-316L, which suits seawater and brackish water desalination as well as clean water boiler feed. The pump is energy efficient, light in weight and needs little maintenance, making it a practical choice for continuous high-pressure duties. We help you choose between a single pump and a series set.
Key highlights
- Flow 16–55 m³/h; head up to 718 m (71.8 bar)
- Maximum working pressure 75 bar
- Back-to-back impellers balance axial thrust
- Single pump or two pumps in series
- SS-304, SS-316 and SS-316L construction
- Power up to 55 kW × 2 at 2900 rpm
Why choose the HP series
Very high pressure
Heads up to 718 m and working pressure up to 75 bar suit reverse osmosis membranes and high-pressure boiler feed.
Balanced thrust
Back-to-back impellers cancel much of the axial thrust, reducing bearing load and supporting longer, smoother operation at high pressure.
Series pump sets
Two pumps can be assembled in series as one set, reaching higher pressures while keeping each pump within its design range.
Corrosion-resistant grades
SS-316 and SS-316L options resist chlorides in seawater and brackish water, protecting the hydraulics in demanding desalination service.
Energy efficient
Efficient hydraulics at high pressure help control running costs on continuous, long-running membrane feed and boiler feed duties.
Low maintenance
A reliable, light-weight design with balanced hydraulics needs little routine attention beyond periodic mechanical seal and bearing condition checks.
HP series performance range
| Flow range (Q) | 16–55 m³/h |
|---|---|
| Delivery head (H) | Max. 718 m (71.8 bar) |
| Maximum working pressure | 75 bar |
| Liquid temperature | -15 °C to +70 °C |
| Speed (N) | 2900 rpm |
| Power (P) | Up to 55 × 2 kW |
| Material of construction | SS-304, SS-316 and SS-316L |
| Configuration | Single pump or two pumps in series; back-to-back impellers |
Where the HP series is used
Not sure this is the right fit?
Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.
From enquiry to a running pump
A simple, engineer-led process — so you get the right pump the first time.
-
Share your duty
Tell us the liquid, flow, head, temperature and where the pump will run.
-
Get a sized proposal
Our engineers select the pump type, model, material and motor that fit the duty point.
-
Supply & installation
We supply the pump or system and can install, align and commission it on site.
-
Service that continues
Preventive maintenance, spares and repairs keep the system running efficiently.
High Pressure Pump — FAQs
Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.
Why are the impellers installed back to back?
At high pressure, each impeller produces axial thrust toward the suction side. Mounting half the impellers facing the opposite direction cancels most of this force. This reduces load on the thrust bearing, lowers vibration and supports longer bearing and seal life on high-pressure duties.
Is the HP series suitable for seawater RO?
Yes, membrane desalination is a primary application. Seawater RO typically needs high feed pressure, which the HP series can provide with heads up to 718 m. SS-316 or SS-316L is recommended for seawater. Send the membrane feed pressure, flow and salinity so we can confirm the selection.
When are two pumps used in series?
When the required pressure exceeds what one pump can deliver efficiently, two pumps can be assembled in series as one set, with the first pump feeding the second. This allows pressures close to the 75 bar working limit while keeping each pump in its efficient range. We will advise whether one or two pumps suit your duty.
Which material grade should I select?
SS-304 suits clean water and boiler feed. SS-316 resists chlorides better and is preferred for brackish and seawater. SS-316L offers improved corrosion resistance at welds for aggressive or high-chloride duties. A water analysis helps us recommend the right grade. For seawater, SS-316 is the usual starting point.
Can it be used for boiler feed above 70 °C?
The standard range covers liquids from -15 °C to +70 °C. Many boiler feed systems run hotter, so the feed water temperature must be checked against the pump rating before selection. Share the deaerator or feed tank temperature and boiler pressure for a suitable recommendation.
What information do you need for a quote?
Send the flow in m³/h, required discharge pressure, inlet pressure, liquid and temperature, salinity or water analysis, power supply and whether a single or duty/standby arrangement is required. For RO, the membrane system design data is the most useful input.
Get an HP high-pressure pump sized for your membrane or boiler
Share your flow, pressure and water details, and we will recommend a single pump or series set with the right material grade.