VTP Series Vertical Turbine Pump for Intakes and Sumps
For river intakes, raw water supply, dewatering and wet-pit sumps that need large flows lifted from below ground. The VTP series is configured to your pit depth, liquid and drive, with flows up to 24,000 m³/h.
- Up to 24,000 m³/h
- Multiple drive options
- Configurable build

Configured to your pit, liquid and drive
The VTP series vertical turbine pump is built to order in a range of configurations, constructions and materials. Lineshafts can be open or enclosed, impellers can be enclosed or semi-open keyed, and the discharge flange can be placed above or below ground. A separate axial thrust bearing assembly carries the hydraulic load.
Drive options include an electric motor, an engine with right-angle gear drive, or a steam turbine, so the pump can run where power is limited or standby drives are needed. The range covers flows up to 24,000 m³/h, heads up to 380 m (38 bar) and liquids up to 80 °C at 2900 or 1450 rpm.
Bowls are cast iron or stainless steel, shafts are stainless steel, impellers are cast iron, bronze or stainless steel, and discharge heads are cast iron or carbon steel. Overall construction is available in CI, DI, CS and duplex steel to suit raw water, effluent or seawater. We configure each pump to your site.
Key highlights
- Flow up to 24,000 m³/h; head up to 380 m (38 bar)
- Open or enclosed lineshaft construction
- Electric motor, engine or steam turbine drive
- Above or below ground discharge
- Separate axial thrust bearing assembly
- CI, DI, CS and duplex steel construction
Why choose a VTP vertical turbine pump
Very high flows
Flows up to 24,000 m³/h suit river intakes, raw water supply schemes and large cooling or dewatering duties.
Flexible configuration
Open or enclosed lineshafts and enclosed or semi-open impellers are chosen to match water quality and maintenance preferences.
Choice of drive
Electric motors, engines with right-angle gear drives or steam turbines let the pump run on available power or as standby.
Material options
Bowls, impellers, shafts and discharge heads are selected in CI, bronze, stainless, carbon steel or duplex to suit the liquid.
Discharge placement
Above or below ground discharge flanges help fit the pump to existing pipework, pump house layouts and site levels.
Dedicated thrust bearing
A separate axial thrust bearing assembly carries hydraulic thrust, protecting the driver and supporting long, reliable pump operation.
VTP series performance range
| Flow range (Q) | Up to 24,000.0 m³/h |
|---|---|
| Delivery head (H) | Max. 380 m (38.0 bar) |
| Maximum liquid temperature | Up to 80 °C |
| Speed (N) | 2900 rpm or 1450 rpm |
| Power (P) | Up to 56 kW |
| Material of construction | CI, DI, CS, duplex steel |
| Bowl | Cast iron, stainless steel |
| Shaft | Stainless steel |
| Impeller | Cast iron, bronze or stainless steel |
| Discharge head | Cast iron or carbon steel |
| Drive options | Electric motor; engine with right-angle gear drive; steam turbine |
Where the VTP series is used
Not sure this is the right fit?
Send us your duty point and site conditions. A pump engineer will check the selection and suggest alternatives if needed.
From enquiry to a running pump
A simple, engineer-led process — so you get the right pump the first time.
-
Share your duty
Tell us the liquid, flow, head, temperature and where the pump will run.
-
Get a sized proposal
Our engineers select the pump type, model, material and motor that fit the duty point.
-
Supply & installation
We supply the pump or system and can install, align and commission it on site.
-
Service that continues
Preventive maintenance, spares and repairs keep the system running efficiently.
Vertical Turbine Pump — FAQs
Straight answers to the questions buyers ask us most. Can't find yours? Ask an engineer directly.
What is a vertical turbine pump?
A vertical turbine pump has its bowl assembly submerged in a pit, well or sump, connected by a column pipe and lineshaft to a driver at the surface. It lifts large volumes from below ground without priming, which makes it suitable for intakes, sumps and deep wells where surface pumps cannot draw water reliably.
Open or enclosed lineshaft, which should I choose?
An open lineshaft uses the pumped water to lubricate the bearings and suits clean water. An enclosed lineshaft protects the shaft and bearings inside a tube with separate lubrication, which is better for water containing sand, silt or effluent. Share your water quality and we will recommend the right construction.
When are engine or steam turbine drives used?
Engine drives with right-angle gearboxes suit sites without reliable power or where a standby driver is required, such as irrigation and flood control. Steam turbines suit plants with surplus steam. Electric motors remain the most common choice where grid power is dependable.
What information is needed to size a VTP?
Send the flow, total head, pit or well depth, minimum and maximum water levels, liquid type and temperature, preferred drive and discharge position. A sketch of the sump or intake helps us check submergence and select the bowl size, column length and lineshaft type.
Which materials suit seawater or effluent?
For seawater, bronze impellers with duplex or stainless components are typically preferred to resist chloride corrosion. For effluent, enclosed lineshafts and stainless or duplex wetted parts help resist corrosion and abrasion. Send a water analysis so we can propose suitable materials.
How are vertical turbine pumps maintained?
Routine checks include thrust bearing lubrication, gland or seal condition, vibration and motor current. Typically bowl and bearing wear depends on sand content and running hours. Planned inspections of the column and lineshaft bearings help avoid unplanned outages on critical intakes.
Get a VTP vertical turbine pump configured for your site
Share your flow, head, pit depth and water quality, and we will configure the bowl, column, materials and drive.